Chlorophyll is one of the most important substances in photosynthesis of plant leaves. The content of chlorophyll is an important indicator of plant photosynthesis ability. For the measurement of chlorophyll content, many domestic and foreign related research, such as extraction of chlorophyll, chlorophyll meter measurement method using acetone, direct extraction of plant chlorophyll blade dimethyl sulfoxide and the like. Each method has its own advantages and disadvantages, but in practical applications, the chlorophyll meter is most frequently used for measurement at this stage because it is the quickest and simplest method. And the accuracy is extremely high.
The chlorophyll content determined by the Arnon filtration method is quite different from other methods. The main reason may be that the Arnon method requires filtration when determining the chlorophyll content, and the filtration process causes a partial loss of chlorophyll content. Arnon centrifugation is slightly more efficient than Arnon filtration. The efficiencies of the chlorophyll content determination by extraction method were as follows: 80% acetone extraction method <95% ethanol extraction method <three mixture solution extraction method <two mixture solution extraction method.
In addition, with the increase of the proportion of ethanol in the mixture, the synergistic effect increases, and the content reaches the maximum when the ratio of ethanol to acetone reaches 1:1; subsequently, ethanol is added to acetone, and the synergistic effect becomes smaller. It can be seen that when the ratio of ethanol to acetone reaches 1:1, the extraction of chlorophyll from Luodianxiaomi walnuts is the most abundant. Experiments with different proportions of synergistic effects showed that when the ratio of anhydrous ethanol to anhydrous acetone was 1:1, the amount of extraction was the largest. Therefore, the single factor test used the above solution as the experimental extraction solution. In the related literature of chlorophyll extraction, three main factors affecting the extraction of chlorophyll were proposed: extraction temperature, extraction time and extract-to-liquid ratio. At the same extraction temperature and extract liquid-liquid ratio, when the extraction time increased from 2 h to 5 h, the chlorophyll content of Luodian walnut groats gradually increased and reached its maximum at 5 h, and then followed by leaching. As time increases, the chlorophyll content continues to decline. This shows that the optimum extraction time of chlorophyll is 5 h, and less than or more than 5 h, the extraction of chlorophyll is not sufficient. This is due to the fact that after leaching begins, there is a process of outward diffusion of chlorophyll from the tissues, so the extracted chlorophyll increases continuously. When the extraction time was 5 h, the diffusion of chlorophyll into the extraction solvent reached the equilibrium and the chlorophyll content in the solution reached the highest. After the leaching time exceeds 5 h, the chlorophyll content in the solution begins to decrease. The probable reason is that with the increase of extraction time, the chlorophyll leakage of Luodian millet walnuts will take longer under light, and the instability of light will cause the chlorophyll content to decrease continuously.
Metal Body Square Water Cooling Tower
This series of products run stable, low noise, energy-saving, in office buildings, shopping malls, hotels, residential areas and other central air-conditioning supporting the use of better results.
The company's standard cooling tower according to the international design conditions design, can also provide customers with non-standard operating conditions or specific sizes under the special, special design.
The circulating water pump suction port shall be located below the water level of the cooling tower catchment basin, and the cooling tower outlet pipe shall not be allowed to be higher than the maximum water level of the catchment basin.
Pipe mounts should be pipe racks and cooling towers should not be allowed to directly bear the weight of the pipes.
The rehydration pipe of the cooling tower should be provided with a support stand to avoid vibration of the pipe when the float valve is rehydrated.
Rehydration pressure should be below 5m water pressure, national standard
The flannage pressure is 1.0Mpa.
When two or more units are assembled, our company will provide a connecting balance tube to balance the chassis water level. The tower top inlet should be set with a conditioning valve in order to enter each
.The water level of the tower is uniform.
The noise is measured at dm1.13VL-W at the equivalent diameter of the cooling tower (Dm1.13VL*W), 1.5 meters above the ground height, wherein L and W are the shape rulers of the tower
inch long and wide).
The use of cellular continuous blister series of diversion,heat dissipation, water collection three-in-one native filler, the whole suspension, gravity cloth water, low drop of water, with cold effect
High, low energy consumption, less drift water, less noise and so on, floating water rate is less than 0.001%.
When connecting different types of towers, the bottom basin water level height of different types of towers must be taken into account, and the base height must be adjusted to maintain the water level balance of the towers.
Metal Body Square Water Cooling Tower,Tower Water Cooler,Water Cooled Cooling Tower,Tower Cooling System